Recall on the Dragon Camming device size 6 – 23/07/2010

23 July, 2010

DMM International has identified a raw material problem that may affect the strength on certain models of the Dragon Cam in size 6 (Product Code A7056A).

This recall only involves the Dragon Cam in size 6 and no other sizes of Dragon Cam are involved.

The problem originates from a structural defect in a raw material that is uniquely used to make a single component on the size 6 Dragon.

The raw material involved is used to make the aluminium axle boss on the Dragon Cam in size 6. DMM International has discovered that the components made out of this defective material can develop cracks and that these cracks can grow and propagate with time. This could cause the units to fail below their rated strength.

The product can be returned via your retailer or directly to DMM so that it can be replaced.

Please accept our sincere apologies for this inconvenience.

PDF information sheet: DMM International Recall on the Dragon Camming Device in size 6

×